Gladiator Pickup Camper USA Size User Guide

Frost Control System

Important Notices

- Damage that may occur in systems exposed to freezing without manual drainage is the responsibility of the user. - Damage to boilers, hoses, and connections resulting from freezing is not covered by the warranty.

The cabin water system includes a frost control valve to provide protection against freezing. This system ensures that water is drained in a controlled manner to prevent the boiler and water pipes from freezing and sustaining damage at low temperatures. The frost control system can operate manually or automatically, depending on the model used. During the defrosting process, the water in the system is drained out from under the cabin. The button indicated by the arrow in the image below is the frost control system's on/off (normal operation – drain) button. This button is used to drain the water system in conditions where there is a risk of freezing. Ensure that the button is in the closed (operating) position during normal use.

Truma FrostControl System

The Truma FrostControl system is an automatic drain-equipped freeze protection valve used to protect water pipes from freezing.

Working Principle & Usage

- When the ambient temperature drops to approximately +3 °C, the system automatically activates and drains the water. - During evacuation, water in the boiler and water pipes is drained out from under the cabin. - Ensure that the valve is in the closed (operating) position during normal use. - The water system should not be left active in conditions where there is a risk of freezing. - Water draining during automatic discharge is normal and is not considered a malfunction. - Even if the system is operational under freezing conditions, necessary precautions must be taken. - Damage that may occur due to freezing is considered user-related and is not covered by the warranty. Important Notices

TST Frost Control System

Working Principle & Usage The TST frost control system is a manually controlled drain valve used to protect water pipes from freezing.

Important Notices - In conditions where there is a risk of freezing, the water system must be drained manually by the user. - When the valve is opened, the water in the boiler and water lines is drained out from under the cabinet. - For long-term parking, winter use, or temperatures below +3 °C , manual drainage must be performed. temperature reaches +4 °C again, the system resets itself. You can use the water system. Use the water system when the interior temperature of the caravan is 7 °C. - It automatically turns on at +3 °C and prevents freezing. When the

31

Made with FlippingBook Annual report maker